Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)

  • Audited Supplier
  • 7 yrs
  • leading factory

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Water Migration Barrier: Composite structure prevents water movement between concrete and membrane.
  • UV & Weather Resistant: Withstands 49 days of UV exposure, rain, and dirt without losing adhesion.
  • Chemical Resistance: Resists acid, alkali, and salt, protecting membranes in harsh environments.
  • Impact & Puncture Proof: High resistance to damage during construction, reducing failure risks.
  • Works in Wet Conditions: Effective overlapping and bonding can be realized even in water.
  • Multi-Application: Suitable for vertical and horizontal areas, including basements and tunnels.
  • Certified Quality: Holds CE, ISO, MSDS, ASTM, and SGS certifications for reliability.

Product Images of Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)

Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)
Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier) pictures & photos
Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)
Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier) pictures & photos
Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)
Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier) pictures & photos
Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)
Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier) pictures & photos
Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)
Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier) pictures & photos
Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)
Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier) pictures & photos
Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)
  • Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)
  • Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)
    Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)
  • Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)
    Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)
  • Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)
    Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)
  • Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)
    Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)
  • Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)
    Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)
  • Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)
    Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)

Find Similar Products

Product Description

MBP Pro,a Professional waterproofing membrane developed for below grade slabs and confined sites of behind basement walls.

Product description:
MBP Pro waterproofing membrane is a special composite sheet comprised of a robust HDPE or TPO layer, a pressure-sensitive adhesive layer and a special protective layer applied to protect adhesive layer from external factors. Thanks to this feature, it is a professional waterproofing membrane in the composite structure which does not allow water to move between the reinforced concrete structure and membrane. The membrane has two sided bonding overlaps.
Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)

Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)




 
Application
Applied either horizontally to smoothly prepared concrete substrate and compacted earth or crushed stone substrate; or vertically to permanent formwork. Concrete is then cast directly against the adhesive side of the membranes.
MBP Pro Membrane is used for the waterproofing of exterior basement walls, foundations, floor plates, etc.The same product is suitable for vertical and horizontal areas. MBP Membrane is usable against pressurized water.
 
  • Waterproofing to basements of industrial and civil engineering.
  • Pre-applied waterproofing system for walls, tunnels and subways.
     
     Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)

     
     
    Advantages
    1.White sheet with non-recycled HDPE or TPO(pellets) as raw materials --easy to identify whether or not add inferior recycled materials .
    2.Pressure sensitive adhesive with excellent physical properties of initial adhesion, cohesive force and peel strength.
    3.Resistant to weather conditions--the specially formulated surface coating ensures that self-adhesive properties withstand up to 49 days of UV exposure, rain water, dirt and contaminants, etc.
    4.Good dimensional stability-- dimensional variation rate does not exceed 0.5%, with smaller wrinkles comparing to similar products.
    5.Resistant against impact and puncture, effectively reduces the possibility of membrane being destroyed during construction.
    6.High resistance to chemicals such as acid, alkali and salt, protect the membranes in most areas of alkaline land or acid rain.
    7. Membranes unaffected by wet jobsite conditions--effective overlapping can be realized in the water.


     
    Installation
    Application-Preparation of the surface
    The surface must be sound, even, stable and clean. The substrate to be coated should not have protrusions, gaps, joints or voids greater than 10 mm. To prevent movements of penetrations such as pipe penetrations for water and electricity during concrete and membrane installation, they have to be fixed and stabilized. Damaged concrete should be renovated with MBP Multi Mortar first. Sharp edges have to be removed first.
    Material- horizontal application
    MBP Membrane must be placed with the granular adhesive coating layer upwards and the white layer facing the substrate.
    The overlapping between the membranes is 75 mm. Before removing the silicone foil(of the overlapping area) ensure that the membranes overlapping edge is positioned correctly. Ensure the back side of each subsequent roll s clean prior to overlapping.
    Then start removing of plastic film to bond the membranes together. Use a heavy roller to ensure a complete perfect bonding between the membranes. Then go ahead with removing of plastic film and press membranes together.
    Material-vertical application
    MBP Membrane must be fixed mechanically to the substrate by using fixing tools. These fixings must have a low profile head so that the membrane won't be damaged from the fixings.
    The overlapping between the membranes is 75 mm. Before removing the plastic film (on the overlapping area)ensure that the membranes overlapping edge is positioned correctly. Ensure the back side of each subsequent roll is clean prior to overlapping.
    Then start removing of plastic film to bond the membranes together. Use a heavy roller to ensure a complete perfect bonding between the membranes. Then go ahead with removing of plastic film and press membranes together.
    Repairs before concrete placement
    In case of damaging the MBP Membrane during installation of formwork and reinforcement steel placement it is necessary to repair prior pouring of concrete.
    Pouring of concrete
    Ensure that all overlapping areas are sealed and the foil is removed in that area. Do not damage the membrane during pouring of concrete.
    Formwork removal
    It is very important not to remove formwork until the concrete has sufficient compressive strength to develop the required adhesion with MBP Membrane. Too early removal of all formworks can lead to a displacement of MBP Membrane and or concrete damage. A minimum concrete compressive strength of 10 N/mm2 recommended prior removing formwork.
    Disclaimer
    The information complies with the current state of development. There is no claim for completeness. A professional and therefore successful processing of the products is not within our responsibility. We accept a warranty only for the quality of the products, but not for processing. It is the responsibility of the user to evaluate the suitability of our products for its purpose. Preliminary tests are recommended.

MBP Pro Technical Data Sheet - Revision Date 01/2019
No. Characteristics Performance Test Standard
1 Max. Tensile Force ≥ 650 N/50mm EN 12311-2:2013
2 Elongation at rapture ≥ %400 EN 12311-2:2013
3 Tear strength ≥ 500 N EN 12310-1:2001
4 Reaction to fire Class E EN 13501-1+A1:2009
5 Static loading ≤20kg EN 12730:2001
6 Joint strenght ≥ 600 N/50mm EN 12317-2:2010
7 Impact resistance ≤700mm EN 12691:2006(Method A)
8 Water tightness Pass (24h/60kPa) EN 1928:2000
9 Durability water tightness after artificial ageing Pass EN 1298:2000
EN 1926:2001
10 Durability water tightness against chemicals Pass EN 1928:2000
EN 1847:2009
Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)

Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)
Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)


Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)
Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)

About the Supplier

This supplier has been audited by BV. Verify the report on the official BV website with ID "MIC-ASR2641350". Items marked "verified" are certified.

Watch Video
Watch Video
Jiangsu Canlon Building Materials Co., Ltd.
Jiangsu Canlon Building Materials Co., Ltd.
Jiangsu Canlon Building Materials Co., Ltd.
Jiangsu Canlon Building Materials Co., Ltd.
Jiangsu Canlon Building Materials Co., Ltd.
Jiangsu Canlon Building Materials Co., Ltd.
Jiangsu Canlon Building Materials Co., Ltd.
Jiangsu Canlon Building Materials Co., Ltd.

About Our Factory & Business Background

Address
No. 8, Hengtong Rd, Qidu Town, Wujiang Dist, Suzhou City Jiangsu Province, 215234, China
Terms of Payment
LC, T/T
International Commercial Terms(Incoterms)
FOB, CFR, CIF, FCA, EXW
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Nearest Port
SHANGHAI, NINGBO, NANJING

Our Production Capability & Technical Expertise

Main Products
Waterproof Membrane, Waterproof Materials, Polyurethane Coating, Single Ply Roofing, Roofing Membrane

Our Industry Experience & Global Business Record

Export Year
2012-03-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What is the primary function of MBP Pro membrane?
It acts as a water migration barrier, preventing water movement between the reinforced concrete structure and the membrane.
Can this membrane be used in wet job site conditions?
Yes, the membrane is unaffected by wet conditions, allowing for effective overlapping and bonding even in water.
How long can the membrane withstand UV exposure?
The specially formulated surface coating ensures self-adhesive properties withstand up to 49 days of UV exposure.
What certifications does the product hold?
The product holds CE, ISO, MSDS, ASTM, and SGS certifications.
What is the recommended concrete strength before removing formwork?
A minimum concrete compressive strength of 10 N/mm2 is recommended prior to removing formwork.
What is the overlapping width between membranes?
The overlapping between the membranes is 75 mm for both horizontal and vertical applications.
Is the membrane resistant to chemicals?
Yes, it has high resistance to chemicals such as acid, alkali, and salt, protecting membranes in alkaline land or acid rain areas.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now