Certification: ISO, MSDS, CE, ASTM, SGS
Thickness: 1.2mm
Type: Waterproof Roll Material
Ceiling Tile Shape: Roll
Material: HDPE
Surface Treatment: Spray Painted
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
MBP-P
Function
Waterproof
Color
White
Usage
Outdoor, Indoor, Underground
Ceiling Tile Type
HDPE
Trademark
CANLON
Origin
China

Product Description

MBP Pro,a Professional waterproofing membrane developed for below grade slabs and confined sites of behind basement walls.

Product description:
MBP Pro waterproofing membrane is a special composite sheet comprised of a robust HDPE or TPO layer, a pressure-sensitive adhesive layer and a special protective layer applied to protect adhesive layer from external factors. Thanks to this feature, it is a professional waterproofing membrane in the composite structure which does not allow water to move between the reinforced concrete structure and membrane. The membrane has two sided bonding overlaps.
Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)

Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)




 
Application
Applied either horizontally to smoothly prepared concrete substrate and compacted earth or crushed stone substrate; or vertically to permanent formwork. Concrete is then cast directly against the adhesive side of the membranes.
MBP Pro Membrane is used for the waterproofing of exterior basement walls, foundations, floor plates, etc.The same product is suitable for vertical and horizontal areas. MBP Membrane is usable against pressurized water.
 
  • Waterproofing to basements of industrial and civil engineering.
  • Pre-applied waterproofing system for walls, tunnels and subways.
     
     Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)

     
     
    Advantages
    1.White sheet with non-recycled HDPE or TPO(pellets) as raw materials --easy to identify whether or not add inferior recycled materials .
    2.Pressure sensitive adhesive with excellent physical properties of initial adhesion, cohesive force and peel strength.
    3.Resistant to weather conditions--the specially formulated surface coating ensures that self-adhesive properties withstand up to 49 days of UV exposure, rain water, dirt and contaminants, etc.
    4.Good dimensional stability-- dimensional variation rate does not exceed 0.5%, with smaller wrinkles comparing to similar products.
    5.Resistant against impact and puncture, effectively reduces the possibility of membrane being destroyed during construction.
    6.High resistance to chemicals such as acid, alkali and salt, protect the membranes in most areas of alkaline land or acid rain.
    7. Membranes unaffected by wet jobsite conditions--effective overlapping can be realized in the water.


     
    Installation
    Application-Preparation of the surface
    The surface must be sound, even, stable and clean. The substrate to be coated should not have protrusions, gaps, joints or voids greater than 10 mm. To prevent movements of penetrations such as pipe penetrations for water and electricity during concrete and membrane installation, they have to be fixed and stabilized. Damaged concrete should be renovated with MBP Multi Mortar first. Sharp edges have to be removed first.
    Material- horizontal application
    MBP Membrane must be placed with the granular adhesive coating layer upwards and the white layer facing the substrate.
    The overlapping between the membranes is 75 mm. Before removing the silicone foil(of the overlapping area) ensure that the membranes overlapping edge is positioned correctly. Ensure the back side of each subsequent roll s clean prior to overlapping.
    Then start removing of plastic film to bond the membranes together. Use a heavy roller to ensure a complete perfect bonding between the membranes. Then go ahead with removing of plastic film and press membranes together.
    Material-vertical application
    MBP Membrane must be fixed mechanically to the substrate by using fixing tools. These fixings must have a low profile head so that the membrane won't be damaged from the fixings.
    The overlapping between the membranes is 75 mm. Before removing the plastic film (on the overlapping area)ensure that the membranes overlapping edge is positioned correctly. Ensure the back side of each subsequent roll is clean prior to overlapping.
    Then start removing of plastic film to bond the membranes together. Use a heavy roller to ensure a complete perfect bonding between the membranes. Then go ahead with removing of plastic film and press membranes together.
    Repairs before concrete placement
    In case of damaging the MBP Membrane during installation of formwork and reinforcement steel placement it is necessary to repair prior pouring of concrete.
    Pouring of concrete
    Ensure that all overlapping areas are sealed and the foil is removed in that area. Do not damage the membrane during pouring of concrete.
    Formwork removal
    It is very important not to remove formwork until the concrete has sufficient compressive strength to develop the required adhesion with MBP Membrane. Too early removal of all formworks can lead to a displacement of MBP Membrane and or concrete damage. A minimum concrete compressive strength of 10 N/mm2 recommended prior removing formwork.
    Disclaimer
    The information complies with the current state of development. There is no claim for completeness. A professional and therefore successful processing of the products is not within our responsibility. We accept a warranty only for the quality of the products, but not for processing. It is the responsibility of the user to evaluate the suitability of our products for its purpose. Preliminary tests are recommended.

MBP Pro Technical Data Sheet - Revision Date 01/2019
No. Characteristics Performance Test Standard
1 Max. Tensile Force ≥ 650 N/50mm EN 12311-2:2013
2 Elongation at rapture ≥ %400 EN 12311-2:2013
3 Tear strength ≥ 500 N EN 12310-1:2001
4 Reaction to fire Class E EN 13501-1+A1:2009
5 Static loading ≤20kg EN 12730:2001
6 Joint strenght ≥ 600 N/50mm EN 12317-2:2010
7 Impact resistance ≤700mm EN 12691:2006(Method A)
8 Water tightness Pass (24h/60kPa) EN 1928:2000
9 Durability water tightness after artificial ageing Pass EN 1298:2000
EN 1926:2001
10 Durability water tightness against chemicals Pass EN 1928:2000
EN 1847:2009
Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)

Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)
Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)


Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)
Mbp Cold-Applied or Pre-Applied Tpo Self Adhesive Waterproof Membrane (Water Migration Barrier)

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
13155300 RMB
Plant Area
>2000 square meters