HDPE/Tpo Pre-Applied Waterproofing Membrane with Ziplap Adhesive

Product Details
Customization: Available
Certification: ISO, MSDS, CE, ASTM, SGS
Thickness: 1.2mm
Still deciding? Get samples of US$ 0/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
13155300 RMB
Plant Area
>2000 square meters
  • HDPE/Tpo Pre-Applied Waterproofing Membrane with Ziplap Adhesive
  • HDPE/Tpo Pre-Applied Waterproofing Membrane with Ziplap Adhesive
  • HDPE/Tpo Pre-Applied Waterproofing Membrane with Ziplap Adhesive
  • HDPE/Tpo Pre-Applied Waterproofing Membrane with Ziplap Adhesive
  • HDPE/Tpo Pre-Applied Waterproofing Membrane with Ziplap Adhesive
  • HDPE/Tpo Pre-Applied Waterproofing Membrane with Ziplap Adhesive
Find Similar Products

Basic Info.

Model NO.
MBP-Pro
Type
Waterproof Roll Material
Ceiling Tile Shape
Roll
Material
HDPE
Surface Treatment
Spray Painted
Function
Waterproof
Color
White
Usage
Outdoor, Indoor, Underground
Ceiling Tile Type
HDPE
Trademark
CANLON

Product Description

General Description
"CANLON" Forfens Smooth is polymer pre-applied waterproof membrane, comprised of white polymer sheet (HDPE or TPO), pressure sensitive adhesive, and weather resistant coating layer. The backside factory lap can enhance the installation and significantly  improve the overlapping strength. In the more extreme jobsite condition (such as rains, water, 
low temperature, etc.).
I
t can also achieve effective connection on factory laps.The installation of the membrane adopts the pre-applied method, which can realize a full bonding with the casted concrete and avoid the water migration.
 
 
                                  HDPE/Tpo Pre-Applied Waterproofing Membrane with Ziplap Adhesive

HDPE/Tpo Pre-Applied Waterproofing Membrane with Ziplap AdhesiveHDPE/Tpo Pre-Applied Waterproofing Membrane with Ziplap Adhesive


 
Thickness(mm) Base Sheet thickness(mm) Width(m) Length ( m )
1.2 >0.7 1/1.2 20/30
1.5 >1.0 1/1.2 20/30
1.7 >1.2 1/1.2 20/30
 
Application
Applied either horizontally to smoothly prepared concrete substrate and compacted earth or crushed stone substrate; or vertically to permanent formwork. Concrete is then cast directly against the adhesive side of the membranes.
Forfens Smooth Membrane is used for the waterproofing of exterior basement walls, foundations, floor plates, etc.The same product is suitable for vertical and horizontal areas. Forfens Membrane is usable against pressurized water.
 
  • Waterproofing to basements of industrial and civil engineering.
  • Pre-applied waterproofing system for walls, tunnels and subways 
  • HDPE/Tpo Pre-Applied Waterproofing Membrane with Ziplap Adhesive

     
    Advantages
    ·Highly flexible
    .Granular coating
    ·Pressure sensitive adhesive
    ·Continuous thickness
    . Simple installation
    · Watertight
    · Highly chemical resistant
     
    Installation
    Application-Preparation of the surface
    The surface must be sound, even, stable and clean. The substrate to be coated should not have protrusions, gaps, joints or voids greater than 10 mm. To prevent movements of penetrations such as pipe penetrations for water and electricity during concrete and membrane installation, they have to be fixed and stabilized. Damaged concrete should be renovated with MBP Multi Mortar first. Sharp edges have to be removed first.
    Material- horizontal application
    ForfensMembrane must be placed with the granular adhesive coating layer upwards and the white layer facing the substrate.
    The overlapping between the membranes is 75 mm. Before removing the silicone foil(of the overlapping area) ensure that the membranes overlapping edge is positioned correctly. Ensure the back side of each subsequent roll s clean prior to overlapping.
    Then start removing of plastic film to bond the membranes together. Use a heavy roller to ensure a complete perfect bonding between the membranes. Then go ahead with removing of plastic film and press membranes together.
    Material-vertical application
    Forfens Membrane must be fixed mechanically to the substrate by using fixing tools. These fixings must have a low profile head so that the membrane won't be damaged from the fixings.
    The overlapping between the membranes is 75 mm. Before removing the plastic film (on the overlapping area)ensure that the membranes overlapping edge is positioned correctly. Ensure the back side of each subsequent roll is clean prior to overlapping.
    Then start removing of plastic film to bond the membranes together. Use a heavy roller to ensure a complete perfect bonding between the membranes. Then go ahead with removing of plastic film and press membranes together.
    Repairs before concrete placement
    In case of damaging the Forfens Membrane during installation of formwork and reinforcement steel placement it is necessary to repair prior pouring of concrete.
    Pouring of concrete
    Ensure that all overlapping areas are sealed and the foil is removed in that area. Do not damage the membrane during pouring of concrete.
    Formwork removal
    It is very important not to remove formwork until the concrete has sufficient compressive strength to develop the required adhesion with Forfens Membrane. Too early removal of all formworks can lead to a displacement of Forfens Membrane and or concrete damage. A minimum concrete compressive strength of 10 N/mm2 recommended prior removing formwork.
    Disclaimer
    The information complies with the current state of development. There is no claim for completeness. A professional and therefore successful processing of the products is not within our responsibility. We accept a warranty only for the quality of the products, but not for processing. It is the responsibility of the user to evaluate the suitability of our products for its purpose. Preliminary tests are recommended.

Forfens Technical Data Sheet - Revision Date 01/2019
No. Characteristics Performance Test Standard
1 Max. Tensile Force ≥ 650 N/50mm EN 12311-2:2013
2 Elongation at rapture ≥ %400 EN 12311-2:2013
3 Tear strength ≥ 500 N EN 12310-1:2001
4 Reaction to fire Class E EN 13501-1+A1:2009
5 Static loading ≤20kg EN 12730:2001
6 Joint strenght ≥ 600 N/50mm EN 12317-2:2010
7 Impact resistance ≤700mm EN 12691:2006(Method A)
8 Water tightness Pass (24h/60kPa) EN 1928:2000
9 Durability water tightness after artificial ageing Pass EN 1298:2000
EN 1926:2001
10 Durability water tightness against chemicals Pass EN 1928:2000
EN 1847:2009
HDPE/Tpo Pre-Applied Waterproofing Membrane with Ziplap Adhesive
HDPE/Tpo Pre-Applied Waterproofing Membrane with Ziplap Adhesive
HDPE/Tpo Pre-Applied Waterproofing Membrane with Ziplap Adhesive


HDPE/Tpo Pre-Applied Waterproofing Membrane with Ziplap Adhesive
HDPE/Tpo Pre-Applied Waterproofing Membrane with Ziplap Adhesive




 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier